Endress+Hauser Proline Promag P 100 electromagnetic flowmeter

The flowmeter for highest medium temperatures with an ultra-compact transmitter

GET INSTANT QUOTE

    FEATURES

    Product Details

    Description

    • Max. measurement error

      Volume flow (standard): ±0.5 % o.r.± 1 mm/s (0.04 in/s)
      Volume flow (option): ±0.2 % o.r. ± 2 mm/s (0.08 in/s

    • Measuring range

      4 dm³/min to 9600 m³/h (1 to 44 000 gal/min)

    • Medium temperature range

      Liner material PFA: –20 to +150 °C (–4 to +302 °F)
      Liner material PFA high‐temperature: –20 to +180 °C (–4 to +356 °F)
      Liner material PTFE: –40 to +130 °C (–40 to +266 °F)

    • Max. process pressure

      PN 40, Class 300, 20K

    • Wetted materials

      Liner: PFA, PTFE
      Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); Tantalum; Platinum; Titanium
      Duplex 1.4462 (UNS S31803)

    Specifications

    • Measuring principle

      Electromagnetic

    • Product headline

      The flowmeter for highest medium temperatures with an ultra-compact transmitter.
      Dedicated to chemical and process applications with corrosive liquids and high medium temperatures.

    • Sensor features

      Diverse applications – wide variety of wetted materials. Energy‐saving flow measurement – no pressure loss due to cross section constriction. Maintenance‐free – no moving parts.
      Nominal diameter: max. DN 600 (24″). All common Ex approvals. Liner made of PTFE or PFA.

    • Transmitter features

      Space‐saving transmitter – full functionality on the smallest footprint. Time‐saving local operation without additional software and hardware – integrated web server. Integrated verification – Heartbeat Technology.
      Robust, ultra-compact transmitter housing. Local display available.

    • Nominal diameter range

      DN 15 to 600 (½ to 24″)

    • Wetted materials

      Liner: PFA, PTFE
      Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); Tantalum; Platinum; Titanium
      Duplex 1.4462 (UNS S31803)

    • Measured variables

      Volume flow, conductivity, mass flow, corrected volume flow, corrected conductivity

    • Max. measurement error

      Volume flow (standard): ±0.5 % o.r.± 1 mm/s (0.04 in/s)
      Volume flow (option): ±0.2 % o.r. ± 2 mm/s (0.08 in/s

    • Measuring range

      4 dm³/min to 9600 m³/h (1 to 44 000 gal/min)

    • Max. process pressure

      PN 40, Class 300, 20K

    • Medium temperature range

      Liner material PFA: –20 to +150 °C (–4 to +302 °F)
      Liner material PFA high‐temperature: –20 to +180 °C (–4 to +356 °F)
      Liner material PTFE: –40 to +130 °C (–40 to +266 °F)

    • Ambient temperature range

      Flange material carbon steel: –10 to +60 °C (+14 to +140 °F)
      Flange material stainless steel: –40 to +60 °C (–40 to +140 °F)

    • Sensor housing material

      DN 15 to 300 (½ to 12″): AlSi10Mg, coated
      DN 350 to 600 (14 to 24″): Carbon steel with protective varnish

    • Transmitter housing material

      AlSi10Mg, coated

    • Degree of protection

      IP66/67, type 4X enclosure

    • Display/Operation

      4‐line backlit display available (no local operation)
      Configuration via web browser and operating tools possible

    • Outputs

      4‐20 mA HART (active)
      Pulse/frequency/switch output (passive)

    • Inputs

      None

    • Digital communication

      HART, PROFIBUS DP, Modbus RS485, EtherNet/IP, PROFINET

    • Power supply

      DC 20 to 30 V

    • Hazardous area approvals

      ATEX, IECEx, cCSAus, INMETRO

    • Other approvals and certificates

       

    • Product safety

      CE, C-Tick

    • Metrological approvals and certificates

      Calibration performed on accredited calibration facilities (acc. to ISO/IEC
      17025)
      Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)

    • Marine approvals and certificates

      LR approval, DNV approval, ABS approval, BV approval

    • Pressure approvals and certificates

      PED, CRN

    • Material certificates

      3.1 material

    • Hygienic approvals and certificates

      Drinking water approval: ACS, NSF 61, WRAS

    Documents

    Documents

    Accessories

    Accessories

    JUHE FUTURE INTERNATIONAL LIMITED

    specializes in distributing test and measurement instruments. We have a professional global service team to provide high-quality and efficient services.

    We will quote within 48 hours.

    It is one year warranty.

    Yes, we have professional engineers who can assist you.

    For non-stock products, the lead time is about 4-6weeks. For individual specialty products, the lead time is 6-8weeks after receiving the deposit payment. The lead times become effective when (1) we have received your deposit, and (2) we have your final approval for your products. If our lead times do not work with your deadline, please go over your requirements with your sale. In all cases we will try to accommodate your needs. In most cases we are able to do so.

    Yes, we always use high quality export packaging. We also use specialized hazard packing for dangerous goods and validated cold storage shippers for temperature sensitive items. Specialist packaging and non-standard packing requirements may incur an additional charge.

    We have professional service team,we will keep update information about production/packing/shipping/delivery when you place an order.

    Customers Also Searched

    Professional supplier of gas cutting machines, pipe gas cutter, oxy-fuel cutting machines, CNC plasma cutting machine, welding rod oven, beveling machine and welding machines supplier in China.Here Are A Few Options You Can Use Alternatively.

    Get free quote

    Have a question? Get in touch instantly using the form below.
    Our customer support team would get back to you soon.

      Get Custom Quote